WW200 Waste Water Concrete and Coating

WW200 Waste Water Concrete & Coating is an acid-resistant, low-permeability solution for manholes, pipe linings, and wastewater infrastructure, offering quick curing and lasting protection.

Waste Water Concrete and Coating

WW200 is a sustainable, environmentally friendly concrete with all the benefits of ultra high performance Cold Fusion Concrete.

  • Acid Resistance: Resistant to the corrosive effects of wastewater chemicals, including sulfuric and hydrochloric acids.
  • Protective Coating: Protects metal and cementitious materials from water infiltration and chemical exposure.
  • Quick Curing: Rapid curing in warm weather, allowing for faster project completion.

Where to Use WW200 Waste Water Concrete and Coatings

WW200 is engineered for demanding wastewater infrastructure projects that require enhanced chemical resistance and rapid curing. It’s the perfect solution for environments where durability and protection from aggressive wastewater chemicals are paramount.

  • Suitable for manhole upgrades, pipe linings, and wastewater infrastructure.
  • Ideal for use in wastewater treatment plants, sewer systems, and other environments exposed to corrosive chemicals.
  • Perfect for quick-turnaround projects.

WW200 Testing and Compliance

WW200 Waste Water Concrete and Coating Test Method Low Range High Range
Bulk Density, PCF ASTMC138 133 138
Compressive Strength, PSI ASTMC579 7500 10000
Bond Strength, PSI ASTMC321 1780 2000
Tensile Strength, PSI ASTMC307 3400 5250
Young’s Modulus, PSI ASTMC469 4.77 X 106 6.8 X 106
Poisson’s Ratio ASTMC469 0.02 0.25
Coefficient Of Expansion, 10-6in/°F 1.86 3.05
Max. Service Temperature, °F 1000 1600
Water Absorption, % ASTMC413 0.04 0.11
Working Time, Minutes ASTMC308 120 180
45% Sulfuric Acid, % Mass Loss ASTMC279 1.00 2.20
57% Nitric Acid, % Mass Loss ASTMC279 0.00 0.00
75% Hydrochloric Acid, % Mass Loss ASTMC279 0.00 0.00
75% Acetic Acid, % Mass Loss ASTMC279 0.50 0.88
98% Sulfuric Acid, % Mass Loss ASTMC279 0.00 0.00
85% Phosphoric Acid, % Mass Loss ASTMC279 0.00 0.00
50% Hydrofluoric Acid, % Mass Loss ASTMC279 5.00 24.80

ASTM C1157 Compliance

Acid Resistance Testing

Chloride, Sulfate, and Hydrocarbon Resistance Testing

Compressive Strength Testing

WW200 Waste Water Concrete and Coating Product Details

Packing, Shelf Life, and Coverage

  • Supplied in 55-pound bags or super sacks
  • 2-year shelf life
  • One bag covers 23 square feet at ¼ inch depth

Directions for Use

Prep: For galvanized metal, apply Fusion Prime at 0.02 gallons per square yard and let cure for 24 hours. For concrete/masonry, remove dirt, debris, and incompatible coatings, and ensure the surface is moist. If exposed to low pH, neutralize, remove damaged concrete, and/or apply Fusion Bond at 0.02 gallons per square yard.

How To Apply: Mix 2 gallons of water per 55-lb bag of WW200 for 2-4 minutes using a high-shear mixer. Adjust for sprayable consistency with rotor stator or squeeze pumps. Apply with standard stucco or nozzle equipment at the specified thickness, ensuring WW200 reaches 6,000 psi before surface placement.

Cleanup: Clean all equipment immediately with water to prevent curing in the applicator.

Is WW200 right for your project? Please contact our team for assistance.

Training & Support

 

Our hands-on approach to training and support sets us apart, providing significantly better service than our competitors. We believe in empowering you with comprehensive training on our products before you apply them, ensuring successful and reliable outcomes.

en_USEnglish